Abstract

Percutaneous intervention with balloon expandable stents has proven to be an effective measure to enhance renal blood flow and control blood pressure in subjects with severe ostial renal artery lesions. A small cohort of these subjects have an ostial bifurcation, which complicates the approach to revascularization. In these cases there is a concern of creating a total side-branch occlusion during balloon expansion. We report two cases of an ostial lesion at a renal artery bifurcation revascularized by employing a sequential dilatation double guidewire technique. Using a single 7F sheath in each case, both renal artery branches were wired, and each branch was predilated and stented in a sequential fashion. Excellent angiographic results were obtained in both cases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.