Abstract
This work presents the design and implementation of a nonlinear control strategy for a three-phase three-level neutral-point-clamped boost rectifier. The adopted control consists of nonlinear feedback linearization technique. The nonlinear state-space model of the rectifier was obtained in the dq0 reference frame. The input/output feedback linearization is then applied and the linearizing control law is derived. Therefore, the resulting model is linearized and decoupled in three independent subsystems. Afterwards, the stabilizing controllers are designed based on linear techniques to control line currents, output, and neutral point voltages. The control law is designed using Simulink/Matlab and applied to the converter via a 1.8-kHz pulsewidth modulator (PWM). Both control law and PWM signals are executed in real time using the DS1104 DSP of dSPACE. A 1.2 kW laboratory prototype is built for validation purposes. The proposed control law robustness is validated for diverse severe load and system parameter variations. It shows robust performance in terms of high power factor, low total harmonic distortion and output voltage ripples, small overshoot, and short settling time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.