Abstract

The aim of this work was to measure the safety and efficacy of single i.v. doses of dolasetron mesilate for the control of emesis caused by single high-dose (at least 6 Gy) radiotherapy to the upper abdomen. The double-blind, placebo-controlled, multicenter study stratified patients on the basis of being naive or nonnaive to radiotherapy. Patients with or without a history of previous chemotherapy were enrolled. Patients were randomized to receive placebo or 0.3, 0.6, or 1.2 mg/kg dolasetron mesilate 30 min before radiotherapy, then monitored for 24 h. Antiemetic efficacy was assessed from the time to the first emetic episode or rescue, from whether there was a complete response (0 emetic episodes /no rescue medication) or a complete-plus-major response (0-2 emetic episodes/no rescue medication), from the severity of nausea (rated by patients and the investigator), and from the investigator's assessment of efficacy. Fifty patients completed the study (owing to changing medical practice, enrollment objectives were not met; consequently, no significant linear dose trend was expected). Pooled dolasetron was superior to the placebo in its effect on the time to first emesis or rescue in radiotherapy-nonnaive patients (P = 0.015). Dolasetron was statistically superior to the placebo in the overall population on the basis of a complete plus major response: 54%, 100%, 93%, and 83% for the placebo and 0.3-, 0.6-, and 1.2-mg/kg doses respectively (P = 0.002). The low response in the highest dose group may be due to an imbalance in the number of chemotherapy-nonnaive patients in that group. Dolasetron was superior to the placebo on the basis of nausea assessed by the investigator (P = 0.024) and administration of rescue medication (P = 0.006). Complete response at the 0.3-mg/ kg dose was superior to results with the placebo (P = 0.050). Treatment-related adverse events were rare, mild to moderate in intensity, and evenly distributed across the four groups. Overall, dolasetron mesilate was effective and well-tolerated in the control of single, high-dose radiotherapy-induced emesis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.