Abstract
After developing a pulsed 8X source for H− beams, we are now testing a cooled, dc version. The design dc power density on the cathode surface is 900 W/cm2, much higher than achieved in any previously reported Penning surface-plasma source. The source is designed to accommodate dc arc power levels up to 30 kW by cooling the electrode surfaces with pressurized, hot water. After striking the arc using a 600-V pulser, a 350-V dc power supply is switched in to sustain the 100-V discharge. Now our tests are concentrating on arc pulse lengths ≤1 s. Ultimately, the discharge will be operated dc. The source is described and the initial arc test results are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.