Abstract
Abstract The reagent described is 5.5 M in perchloric acid and 3.3 M in urea. It contains ferric ions, mercuric thiocyanate, mercuric ions (from mercuric perchlorate), and mercuric chloride. Serum dissolves directly in this reagent to yield a clear, reddish solution. When chloride ions are added, they combine first with the free mercuric ions, and then with some of the mercuric ions from the mercuric thiocyanate. Liberated thiocyanate combines with ferric ions to yield red ferric thiocyanate. The color is much more intense in the presence of strong perchloric acid than in other aqueous acid mixtures, Its intensity can be regulated at will by changing the concentration of the ferric iron. The presence of mercuric chloride in the reagent improves linearity between absorbance and chloride concentration. After the total absorbance is determined, compensation for absorbance by other substances is secured by adding mercuric ions to the photometer tube to reverse the color-producing reaction of chloride, reading the residual absorbance, and subtracting it from the total absorbance, to give a net absorbance produced by chloride alone.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.