Abstract
Until now, direct control methods have been mainly investigated and used in conjunction with voltage source converters. In this paper, the authors develop a direct current control method for matrix converters. There are two objectives for the direct current control: the desired current has to be impressed into the load, and the current, drawn from the mains, should be in phase with the voltage and should be (nearly) sinusoidal. This implies active damping of the 400 Hz resonance or the line filter. The method is implemented on a DSP and tested on a 10 kVA matrix converter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.