An accurate and rapid characterization of a thermoelectric module (TEM) is critical to understand the problems in module design and fabrication. We describe an apparatus and a method that directly measure the cooling performance of a TEM such as current for maximum cooling (Imax), maximum cooling power (Qc,max), and maximum temperature difference (ΔTmax). The apparatus is designed based on a finite element model to ensure a simple heat flow measurement. We evaluate the module performance metrics based on differential measurement between the cooling powers with temperature difference across the module under transient conditions. The use of transient data reduces measurement time, and the use of a differential technique enables compensation of the thermal losses. The measured data fit well with conventional theoretical relations for the TEM performance metrics. We test a commercial TEM and validate the results using the Harman method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.