Abstract
In this paper, the design for an electromagnetic structure and reduction cogging torque of a dual generator structured RFPM generator, which is a combination of the inner- and outer-rotor types, has been proposed. We call this a dual generator radial flux permanent magnet generator. To reduce the cogging torque, firstly, stator tooth pairing was designed; secondly, stator displacement was designed and finally, stator tooth pairing and stator displacement were carried out simultaneously. We found the optimal design condition about stator tooth pairing angle combination and stator displacement angle for cogging torque minimization. As a result, a cogging was reduced by 93.3[%] by this study.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.