Abstract

This paper proposes a design method for Z-source network based on inductor current. In Z-source inverter, when the variation of the output current from the Z-source network is large, the variation of the inductor current and the capacitor voltage increase in the Z-source network. Therefore, discontinuous current mode (DCM) condition transiently occurs in the Z-source network inductors. DCM condition affects the operation of the Z-source inverter. Against the problem, this paper proposes a new design method of the Z-source inverter to maintain continuous current mode (CCM) condition. The proposed method is confirmed by simulation results with PSIM and circuit experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.