Abstract

When the pulse current method is used for partial discharge (PD) monitoring of mining cables, the detected PD signals are seriously disturbed by the field noise, which are easily submerged in the noise and cannot be extracted. In order to realize the effective separation of the PD signal and the interference signal of the mining cable and improve the signal-to-noise ratio of the PD signal, a denoising method for the PD signal of the mining cable based on genetic algorithm optimization of variational mode decomposition (VMD) and wavelet threshold is proposed in this paper. Firstly, the genetic algorithm is used to optimize the VMD, and the optimal value of the number of modal components K and the quadratic penalty factor α is determined; secondly, the PD signal is decomposed by the VMD algorithm to obtain K intrinsic mode functions (IMF). Then, wavelet threshold denoising is applied to each IMF, and the denoised IMFs are reconstructed. Finally, the feasibility of the denoising method proposed in this paper is verified by simulation and experiment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call