Abstract
One of the most crucial parameters in operating a vacuum interrupter (VI) is internal pressure. The failure of switching or insulation occurs when the pressure rises above a specific level. Characteristics of partial discharge (PD) in VI can be used to measure the internal pressures of VI. This paper defines a classification problem for the degree of internal pressure in VI using PDs, which were measured using a capacitive PD coupler. Then, we propose a deep neural network to monitor the internal pressure of VI by analyzing PDs. Experimental results show that the proposed deep neural network monitors the internal pressure range, from 1.0 ×10<sup>-2</sup> torr to 10 torr in VI. The classification performance of the proposed method is significantly better than those of machine learning algorithms such as support vector machines and <i>k</i>-nearest neighbor algorithm and the proposed method achieves an 100% classification accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.