This paper describes the construction of a multi-level underground car park within a diaphragm wall in London Clay by the top down technique. The techniques used for diaphragm wall and pile construction under bentonite from existing ground level are reported. Column installation is described, followed by the excavation procedures and the method of construction of the sub-structure floors. Pin piling and casting of the lowest basement slabs completed the construction. An outline of the diaphragm wall and ground movements is presented. The as-built programme is presented and conclusions drawn. (A)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Civil Engineers - Civil Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.