Abstract

Four-level inversion is realised by connecting two two-level inverters, fed from both ends of open-end winding induction motor with Asymmetrical DC link voltages in the ratio of 2:1. This inverter scheme produces 64 space-vector combinations distributed over 37 space-vector locations. All the switching combinations are not helpful to achieve four level inversion, some of the combinations overcharge DC-link capacitor of the inverter operating with a lower DC-link voltage of V dc /3 by other inverter with higher DC-link voltage of 2V dc /3. Decoupled space vector PWM switching strategy is described to eliminate the overcharging effect. Isolated DC power supplies are employed to avoid the zero-sequence currents. Simulation and experimental results are presented in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.