Abstract
Abstract With the technology development of energy conversion, multi-energy flow containing electricity, gas and heat is becoming tightly integrated in regional integrated energy systems (RIESs). Interactions and complementarities of various energy systems can bring more environmental and economic benefits but also security problems. This paper studies a decomposed solution of multi-energy flow considering operational constraints, the energy coupling part is analyzed with the concept of energy hub (EH). Multi-energy flow calculation is verified in case study under conditions of different disturbance in EH, showing the necessarily of operational constraint concern. In addition, a multi-energy flow regulation is discussed utilizing gas load-pressure sensitivity analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.