Abstract

AbstractA hydrostatic drivetrain transmits wind turbine energy to a generator. One hydrostatic transmission system (HTS) configuration utilizes a fixed displacement pump and a variable displacement motor. The system dynamics are captured in a nonlinear multi‐input multi‐output mathematical model. This paper introduces a decentralized control configuration based on this model to achieve two desired objectives: maximizing the harvested energy without direct measurement of wind and regulating the frequency of the generator without using power electronic converters. To accomplish these objectives, suitable pairing of control actuators and system responses are identified through nonlinear relative gain arrays (RGA) analysis. The pairing also provides a strong decoupling of control loops. So maximum power point tracking (MPPT) is achieved independently while the generator speed is regulated to maintain the frequency of generated power at 60 Hz. Simulation results demonstrate robust performance of MPPT and frequency regulation in the presence of uncertainties in the turbine and HTS model. We also demonstrate that the RGA paired input‐out control configuration offers superior performance over other possible input–output paired control configurations.