Abstract

This paper adopts a synthesis algorithm which combines FIR filters and wavelet threshold de-noising method to complete ECG de-noising. Firstly, we designed a FIR equiripple bandpass filter using Matlab FDATool to remove baseline drift, power interference and the high frequency part of muscle moments. Then we adopted an improved wavelet threshold de-noising algorithm to remove the remaining muscle moments with less decomposing levels. The algorithm was implemented on Matlab platform. The experimental results show that the algorithm is simple in design and has less calculation and good de-noising effect, which is superior to conventional wavelet threshold de-noising algorithm, and can be used in clinical analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.