A new model-reference data-driven approach is presented for synthesizing controllers for the CERN power converter control system. This method uses the frequency response function (FRF) of a system in order to avoid the problem of unmodeled dynamics associated with low-order parametric models. For this particular application, it is shown that a convex optimization problem can be formulated in the H ∞ sense to shape the closed-loop FRF while guaranteeing the closed-loop stability. This optimization problem is realized by linearizing a non-convex constraint around a stabilizing operating point. The effectiveness of the method is illustrated by designing a controller for the SATURN power converter which is used in the Large Hadron Collider, in injector machines, and for pulsed applications at CERN. Experimental validation in the frequency-domain is also presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.