Abstract

Due to the complex operating environment, current mismatch faults often occur in photovoltaic (PV) strings in the actual PV plants, which seriously reduces the power of the entire string. This paper investigates and collects the data of mismatched PV strings in an actual PV plant, and further the fault characteristics of mismatched PV strings are extracted through the I-V curve. A data-driven online diagnosis method for current mismatch faults based on string I-V data is proposed. The method uses the I-V data to construct a detection line, and the inflection point and step features on the I-V curve caused by current mismatch can be detected simply and quickly through the parallel movement of the detection line and the positional relationship between the line and the I-V data. The experimental verifications from the actual PV plant are demonstrated to show the effectiveness of the proposed method for PV string current mismatch fault.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.