BackgroundOne of the major concerns in implantable optoelectronics is the heat generated by emitters such as light emitting diodes (LEDs). Such devices typically produce more heat than light, whereas medical regulations state that the surface temperature change of medical implants must stay below + 2 °C. The LED’s reverse current can be employed as a temperature-sensitive parameter to measure the temperature change at the implant’s surface, and thus, monitor temperature rises. The main challenge in this approach is to bias the LED with a robust voltage since the reverse current is strongly and nonlinearly sensitive to the bias voltage.MethodsTo overcome this challenge, we have developed an area-efficient LED-based temperature sensor using the LED as its own sensor and a CMOS electronic circuit interface to ensure stable bias and current measurement. The circuit utilizes a second-generation current conveyor (CCII) configuration to achieve this and has been implemented in 0.35 μm CMOS technology.ResultsThe developed circuits have been experimentally characterized, and the temperature-sensing functionality has been tested by interfacing different mini-LEDs in saline models of tissue prior to in vivo operation. The experimental results show the functionality of the CMOS electronics and the efficiency of the CCII-based technique with an operational frequency up to 130 kHz in achieving a resolution of 0.2 °C for the surface temperature up to + 45 °C.ConclusionsWe developed a robust CMOS current-mode sensor interface which has a reliable CCII to accurately convey the LED’s reverse current. It is low power and robust against power supply ripple and transistor mismatch which makes it reliable for sensor interface. The achieved results from the circuit characterization and in vivo experiments show the feasibility of the whole sensor interface in monitoring the tissue surface temperature in optogenetics.

Highlights

  • One of the major concerns in implantable optoelectronics is the heat generated by emitters such as light emitting diodes (LEDs)

  • We explored the use of LED as their own temperature sensors by using the LED reverse current as a junction temperature-sensitive parameter (TSP)

  • We demonstrate a capacity to sense over a broad range of 12 °C and utilize the technique to explore the surface temperature change on a LED optrode as a function of LED drive current

Read more

Summary

Introduction

One of the major concerns in implantable optoelectronics is the heat generated by emitters such as light emitting diodes (LEDs). The challenge is when the sensor signal is both small and highly sensitive to other factors than the main physical parameter Such factors can be compounded with the need to consume low power and frugal dimensions. As tissue is not transparent, a very high-radiance source is required in addition to genetic manipulation tools Such a source should either be a high-radiance surface stimulator or an arrangement of penetrating optical probes which can deliver light close to the target neurons. An example of the former was developed for retinal prosthesis by Soltan et al [3]. The latter case devices are typically called ‘optrodes’, and a specific example is provided by Ramezani et al [4]

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.