Abstract

This paper presents the new switching converter model used for analyzing the generation mechanism of ringing ground leakage (GL) current, generated during the transient, at switch on/off of any switching converter. By applying the Norton model, the proposed new model of switching converter can be formulated. The ringing GL current is evaluated at the switching on/off of the unbalanced (half-bridge converter) and the balanced converter (full-bridge converter) for bidirectional D.C. motor drive used as an example. It is concluded that the measured and simulated results of the generated GL current agree well with the numerical analysis results, analyzed by the proposed new model of switching converter, in terms of the minimum or maximum peak currents and the ringing frequency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.