Abstract
A cryogenic tritium ( 3H 2) gas target system was constructed and used for a program of electron scattering studies. The 3H 2 was supplied and safely stored as solid U 3H 3. For the experiments, it was transferred to a thin walled cylindrical cell, where it was exposed to 25 μA electron beams with energies up to 800 MeV. During operation, the target cell contained 115000 Ci of tritium at 225 psia and 45 K. Multiple safety enclosures surrounded both target and gas transfer systems. A microprocessor-based control and monitoring system presented target parameters to the operators, identifying those out of range. The target system operated safely and effectively for about 2000 h, enabling completion of comprehensive elastic and elastic electron scattering study of the three nucleon system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.