Abstract

The internal tracer method for estimating contaminant degradation rates separates the attenuation effects not associated with degradation by using a codisposed recalcitrant internal tracer to normalize the degrading contaminant concentration. The remaining attenuation between the internal tracer and degrading contaminant is attributed to degradation and the degradation rate half-life is estimated from the first-order decay equation. An analytical solution of the advection- dispersion equation was used to evaluate flow-and-transport conditions that could result in incorrect estimates of contaminant degradation rate constants. Flow-and-transport characteristics that result in overestimating degradation rates were of particular interest because the internal tracer method often used to demonstrate natural attenuation can achieve remedial objectives. The analytical solution was also used to estimate the magnitude of error associated with using the internal tracer method at an example site and to explain different degradation rates estimated using tracers with different decay rate constants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.