Abstract

We appraised the methodology, execution and quality of the five published meta-analyses that are based on the five randomized controlled trials which compared cardiotocography (CTG)+ST analysis to cardiotocography. The meta-analyses contained errors, either created de novo in handling of original data or from a failure to recognize essential differences among the randomized controlled trials, particularly in their inclusion criteria and outcome parameters. No meta-analysis contained complete and relevant data from all five randomized controlled trials. We believe that one randomized controlled trial excluded in two of the meta-analyses should have been included, whereas one randomized controlled trial that was included in all meta-analyses, should have been excluded. After correction of the uncovered errors and exclusion of the randomized controlled trial that we deemed inappropriate, our new meta-analysis showed that CTG+ST monitoring significantly reduces the fetal scalp blood sampling usage (risk ratio 0.64; 95% confidence interval 0.47–0.88), total operative delivery rate (0.93; 0.88–0.99) and metabolic acidosis rate (0.61; 0.41–0.91).