Abstract
According to the experimental data of the orifice discharge coefficient for the flow through a vertical sharp-edged orifice obtained in the previous study of this work, a theoretical criterion for flow mechanisms of small orifice (viz. thick-walled orifice and nozzle) and large orifice (viz. thin-walled orifice) was proposed based on the ratio of orifice diameter to plate thickness. It can help explain the dissipation of the mechanical energy loss in the flow process for the two flow mechanisms under different operating regimes. The main parameters such as orifice diameter, plate thickness and liquid head were correlated, and a semi-empirical model for orifice coefficient and an empirical model with high precision at the stable region were developed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.