Abstract
The increased use of DC renewable energy resources and DC storage systems, combined with the necessary reduction of energy waste, is boosting the development of DC smart grids. In this scenario, DC load emulation is of great importance. From the hardware point of view, DC buses stability of smart grids and the different DC/DC converter topologies must be tested. From the software point of view, smart grid strategies and job schedulers must be tested with different power absorption profiles. Moreover, DC load emulation can be useful for many other purposes, such as battery characterization, power supply testing, photovoltaic I-V curve measurements, etc. In this work, a cost-efficient DC Active Load (AL) solution is proposed. The principle of the circuit topology is a buck-boost-derived converter. This solution can be designed and tested considering the required voltage, current, and maximum input power. Both simulation and experimental results are shown on a 400 W size prototype. Thermal and electrical results validate the simulation model and the AL feasibility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.