Abstract
Ten fellowship-trained pediatric orthopaedic surgeons assessed fracture displacement in 6 patients with displaced medial epicondyle fractures using radiographic views (anteroposterior, lateral, axial, internal oblique [IO], and external oblique [EO]) and computed tomographic (CT) views (axial, 3-dimensional [3D] horizontal, and 3D vertical). Raters used a corresponding point method for measuring displacement. For each image, raters measured the absolute displacement, categorized the percent of displacement relative to the size of the fragment and fracture bed, and indicated a treatment option. Interobserver reliability was calculated for each view. Bland-Altman plots were constructed to evaluate the bias between each radiograph and the mean of the CT methods. For absolute displacement, anteroposterior and EO views showed almost perfect interobserver reliability, with an interclass correlation coefficient (ICC) of 0.944 for the anteroposterior view and an ICC of 0.975 for the EO view. The axial view showed substantial reliability (ICC = 0.775). For the displacement category, almost perfect reliability was shown for the anteroposterior view (ICC = 0.821), the axial view (ICC = 0.911), the EO view (ICC = 0.869), and the IO view (ICC = 0.871). Displacement measurements from the anteroposterior, axial, and EO views corresponded to the measurements from the CT views with a mean bias of <1 mm for each view. However, the upper and lower limits of agreement were >5 mm for all views, indicating a substantial discrepancy between radiographic and CT assessments. Treatment recommendations based on CT changed relative to the recommendation made using the anteroposterior view 29% of the time, the EO view 41% of the time, and the axial view 47% of the time. Using a corresponding point measurement system, surgeons can reliably measure and categorize fracture displacement using anteroposterior, EO, and axial radiographic views. CT-based measurements are also reliable. However, although the mean difference between the radiograph-based measurements and the CT-based measurements was only about 1 mm, the discrepancy between radiographic views and CT-based methods could be as large as 5 to 6 mm. Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.