Abstract

Summary A new correlation and set of pressure-response and pressure-derivative type curves are presented for interference test analysis. The influence of wellbore storage and skin effects at active and observation wells on interference pressure response is examined. In the case of wellbore storage and skin in one well, the correlating parameter [CDe2s]CD/rD2 is used to combine wellbore storage and skin variables in a way that makes it possible to display, on a single type curve, all interference test data that would ordinarily require a number of type curves for various combinations of CD/rD2 and CDe2s. The product of the correlating parameter is used when wellbore storage and skin effects are active at both wells. The difference in the shapes of the single-well storage type curves compared to the two-well storage case at early times can be used as a diagnostic feature in interference testing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.