Abstract
A compact high-voltage pulse generator is designed for control of TDI thyratrons in grounded-cathode thyratron-switching circuits. The unit is the part of the pulse voltage generator for charging a double forming line of the frequency electron accelerator. The unit is controlled from the GZI-6 external generator with a maximal repetition rate of 50 s−1. The unit produces negative-polarity firing voltage pulses with a ∼18-kV/μs rate of pulse rise and allows one to fire simultaneously two TDI4-100k/75PD thyratrons. The scatter of amplitudes of currents of thyratrons, connected in parallel without additional current-dividing circuits, does not exceed 1%. The efficiency factor of the control unit is approximately 85%. The active elements of the control unit are the thyristor and the TGI-500/16 low-power pulse hydrogen thyratron.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.