Abstract
The formation mechanism and control method of flow maldistribution for fuel-cooled plate were studied in this work. The experimental results demonstrated that the irreversible flow maldistribution occurred when the fuel temperature reachedabout 1003 K, and led to severe local overheating as well as coke deposition. Orifices were applied as flow controllers to generate choked flow and to cut off the positive feedback circle of flow rate deviation. The model of choked flow based on real gas state equations was established. Using the model, the features and triggering conditions of choked flow were analyzed. Then 3-D numerical simulation was conducted, and the detail of flow distribution and the stability of the control method were further studied. The results of simulation indicated that, the orifice with choked flow could maintain uniform flow distribution and heat transfer under asymmetric channel structure and backpressure. By means of the control method of choked flow, the fuel-cooled plate kept uniform heat exchanging when the outlet fuel temperature reached 1053 K in the electric heating experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.