Abstract

BackgroundWhen mathematical modelling is applied to many different application areas, a common task is the estimation of states and parameters based on measurements. With this kind of inference making, uncertainties in the time when the measurements have been taken are often neglected, but especially in applications taken from the life sciences, this kind of errors can considerably influence the estimation results. As an example in the context of personalized medicine, the model-based assessment of the effectiveness of drugs is becoming to play an important role. Systems biology may help here by providing good pharmacokinetic and pharmacodynamic (PK/PD) models. Inference on these systems based on data gained from clinical studies with several patient groups becomes a major challenge. Particle filters are a promising approach to tackle these difficulties but are by itself not ready to handle uncertainties in measurement times.ResultsIn this article, we describe a variant of the standard particle filter (PF) algorithm which allows state and parameter estimation with the inclusion of measurement time uncertainties (MTU). The modified particle filter, which we call MTU-PF, also allows the application of an adaptive stepsize choice in the time-continuous case to avoid degeneracy problems. The modification is based on the model assumption of uncertain measurement times. While the assumption of randomness in the measurements themselves is common, the corresponding measurement times are generally taken as deterministic and exactly known. Especially in cases where the data are gained from measurements on blood or tissue samples, a relatively high uncertainty in the true measurement time seems to be a natural assumption. Our method is appropriate in cases where relatively few data are used from a relatively large number of groups or individuals, which introduce mixed effects in the model. This is a typical setting of clinical studies. We demonstrate the method on a small artificial example and apply it to a mixed effects model of plasma-leucine kinetics with data from a clinical study which included 34 patients.ConclusionsComparisons of our MTU-PF with the standard PF and with an alternative Maximum Likelihood estimation method on the small artificial example clearly show that the MTU-PF obtains better estimations. Considering the application to the data from the clinical study, the MTU-PF shows a similar performance with respect to the quality of estimated parameters compared with the standard particle filter, but besides that, the MTU algorithm shows to be less prone to degeneration than the standard particle filter.

Highlights

  • When mathematical modelling is applied to many different application areas, a common task is the estimation of states and parameters based on measurements

  • We present an application of our measurement time uncertainties (MTU)-Particle Filter (PF) method to a pharmacokinetic and pharmacodynamic (PK/PD) study in a non-linear mixed-effects setting in direct comparison with the standard particle filter

  • Motivating example - results we resume our motivating example and use it in a parameter estimation setting to compare our MTU filter to both the standard particle filter and to a state-ofthe-art Maximum Likelihood (ML) method which is not based on Monte Carlo techniques

Read more

Summary

Introduction

When mathematical modelling is applied to many different application areas, a common task is the estimation of states and parameters based on measurements With this kind of inference making, uncertainties in the time when the measurements have been taken are often neglected, but especially in applications taken from the life sciences, this kind of errors can considerably influence the estimation results. A typical population experiment in the PK/PD context consists in the analysis of the contents of the blood plasma of several individuals with respect to concentrations of certain molecules of interest For this purpose, blood probes have to be taken from each individual at certain (fixed) time points after a certain event has occurred (e.g. a drug or a labelled substance has been applied). We will present a modification of the Particle Filter (PF) algorithm (which we call MTU-PF) which is able to fully include a statistical model of the time uncertainties

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.