Abstract

A compact, cryocooler cooled Nb/sub 3/Sn superconducting magnet system for a Cerenkov free electron laser has been designed, fabricated and tested. The magnet is positioned directly behind the electron gun of the laser system. The solenoidal field compresses and guides a tube-shaped 100 A, 500 kV electron beam. A two-stage GM cryocooler, equipped with a first generation ErNi/sub 5/ regenerator, cools the epoxy impregnated solenoid down to the operating temperature of about 7.5 K. This leaves a conservative operational margin for the MJR type of Nb/sub 3/Sn conductor of about 350% (I/sub c/) at 3T. Current leads with HTS sections between the first and second stage of the cryocooler effectively reduce the conductive heat leak. In the warm bore, 60 mm in diameter and 680 mm long, an operational magnetic field of 2 T has been achieved during laser operation without any quench. The field homogeneity is better than 99.5% over 450 mm axial length. Design details and test results of this magnet system are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.