Abstract

This paper presents a condition-monitoring method of dc-link capacitors used in a high-power three-phase PWM inverter with an evaluation circuit intended for ageing tests. Although its power rating is 1/25 of the inverter, the evaluation circuit provides the equivalent ripple current waveform and dc-bias voltage to the high-power inverter. The monitoring method independently extracts the capacitance and ESR of the dc-link capacitor, where the fast Fourier transform is introduced to the ripple current waveform and the dc-link voltage of the evaluation circuit. Experimental results verify that the monitoring method obtains both the ESR and capacitance changes of a capacitor under test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.