Abstract

A practical approach to modeling large systems in terms of simplified component models is presented. The modeling approach uses a state variable formulation and provides practical techniques for predicting the transient response of large, closed loop systems using presently available computer-aided circuit analysis programs. A simplified terminal model for a J-K flip-flop is developed, and five flip-flop models are used to model a divide by twenty counter. Using the system model, the response of the counter in an ionizing radiation environment is determined.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.