Abstract

A system for acoustic analysis of pathological voices is proposed. The vocalized part of the voice signal is separated and all glottal cycles are traced by means of a cross-correlation detector. Based on the so determined beginning and duration of all glottal cycles, shimmer, jitter, several harmonics-to-noise ratios and other widely used acoustic parameters are calculated. New parameters are also introduced for estimation of the turbulent noise in voice signals (Turbulent Noise Index — TNI) and for the “breathy” voice characterization (Normalized First Harmonic Energy — NFHE). These parameters are applied for laryngeal pathology detection. An identification accuracy of 96.1% by the K-nearest neighbors’ method has been achieved. The system is clinically tested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.