Abstract

Long-horizon direct model predictive control (MPC) has pronounced computational complexity and is susceptible to parameter mismatches. To address these issues, this paper proposes a solution that enhances the robustness of long-horizon direct MPC, while keeping its computational complexity at bay. The former is achieved by means of a suitable prediction model of the drive system that enables the effective estimation of the total leakage inductance of the machine. For the latter, the objective function of the MPC problem is formulated such that, even though the drive behavior is computed over a long prediction interval, only a few changes in the candidate switch positions are considered. The effectiveness of the proposed approach is demonstrated with a medium-voltage (MV) drive consisting of a three-level neutral point clamped (NPC) inverter and an induction machine (IM).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.