Abstract

An empirical frictional correction factor to the isentropic nozzle model has been developed for application to refrigerant leakage modeling in scroll, rotary and other similar compressors and expanders. This correction factor is derived by calculating the leakage mass flow rate with a compressible, variable area, real gas properties model and referencing the results to an isentropic nozzle model. The ratio of flows is correlated to the Reynolds number, a characteristic length and the leakage gap width. A representative selection of fluids and geometries are employed. For all the correlations, at least 93% of the points are predicted within an absolute error band of 20%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.