Abstract
Computational fluid dynamics models of wind-dominated and wind and buoyancy-influenced ventilation in a naturally ventilated livestock building were developed to investigate the mixing characteristics of the building and to determine its ventilation efficiency when different cladding materials are used at the eave openings. Firstly, CFD was used to provide insight into the air mixing characteristics of the building during wind-driven and wind and buoyancy-influenced ventilation. Secondly the relationship between an eave opening’s resistance to airflow and indoor air mixing during wind-dominated ventilation was quantified, and finally the effect of eave opening conditions (i.e. eave cladding type, porosity, height) on building ventilation rate was analysed for a range of wind speeds. Overall, this study found the porosity of the eave opening cladding system heavily influenced the mixing of indoor air during wind-driven ventilation, with the low porosity cladding significantly enhancing the building’s ventilation efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.