Abstract

Abstract In this study, a comprehensive investigation of the Ag-Al bond degradation mechanism in an electrically failed module using the argon ion milling, scanning electron microscopy (SEM), dual beam focused ion beam-SEM, scanning transmission electron microscopy energy dispersive x-ray spectroscopy, and time-of-flight secondary ion mass spectrometry is reported. It is found that the bond degradation is due to the galvanic corrosion in the Ag-Al bonding area. Specific attention is given to the information of microstructures, elements, and corrosive ions in the degraded bond. In this study, it is believed that the Ag-Al bond degradation is highly related to the packaging designs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call