Abstract
The mucosal coating properties, liability to bubble formation and palatability of a new barium sulphate suspension (Micropaque HD) were compared with those of the barium suspension shown by previous trials to produce the best results (E-Z-HD). The results show that E-Z-HD gave significantly better mucosal coating and was less liable to bubble formation. There was no significant difference in the palatability of the two preparations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.