Abstract

This study investigates capsule puncture in dry powder inhalers. Gelatin and hydroxypropylmethyl cellulose (HPMC) capsules (stored at 11 and 33% relative humidities) were punctured using a pin from a Foradil® inhaler, with insertion force measurement via an Instron tester. In HPMC capsules, the force after capsule puncture reduced by half and then increased to a second maximum as the pin shaft entered the hole. In gelatin capsules, the postpuncture force reduced to zero, indicating shell flaps losing contact with the pin. At lower moisture contents, both capsules were less flexible. This provides a tool to measure the shell properties of inhalation capsules.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.