Abstract

The standard deviation of the average run length (SDARL) is an important performance metric in studying the performance of control charts with estimated in-control parameters. Only a few studies in the literature, however, have considered this measure when evaluating control chart performance. The current study aims at comparing the in-control performance of three phase II simple linear profile monitoring approaches; namely, those of Kang and Albin (2000), Kim et al. (2003), and Mahmoud et al. (2010). The comparison is performed under the assumption of estimated parameters using the SDARL metric. In general, the simulation results of the current study show that the method of Kim et al. (2003) has better overall statistical performance than the competing methods in terms of SDARL values. Some of the recommended approaches based solely on the usual average run length properties can have poor SDARL performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.