Abstract

A comparative study of the occupant comfort (neutral) in a conventional high-rise office block and a contemporary environmentally-concerned building for Sheffield UK climate conditions was carried out. A questionnaire was designed for occupants to rate their workplace environment in terms of the thermal, visual, acoustic and overall perception and satisfaction level. The basic physical parameters were measured at the same time, e.g. air temperature, humidity, illuminance and sound level. It is inferred that (1) There is a noticeable difference between the conventional building and environmentally-concerned building in terms of their thermal and visual environment. (2) A clear distinction of the occupant sensation and satisfaction level towards their thermal and visual environment is presented between these two buildings. (3) The effect of basic physical variables on the occupants’ perception and satisfaction level becomes less significant when minimal standards are attained. (4) The acoustic satisfaction level however, was not perceived differently by the occupants of the two building types.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.