Abstract

Distillation has relatively low thermodynamic efficiency, so it is a prime target for process intensification studies. The current research aims to study exergy losses in various heat-integrated distillation columns. A conventional industrial-scale i-butane/n-butane fractionator has been selected as a case study for the comparison of the performances of various heat-integrated designs. The Aspen Plus® process simulator is used to perform steady-state simulations and exergy analyses of the conventional distillation column (CDC), internally heat-integrated distillation column (iHIDiC), externally heat-integrated double distillation columns (EHIDDiC), and vapor recompression (VRC) systems. The results of these exergy analyses show that a modified VRC system (ηE = 10.69%) is the most efficient design for this separation. The exergy efficiency of the conventional VRC system is the same as that of the CDC (ηE = 9.27%). The EHIDDiC system (ηE = 9.77%) is somewhat better than the CDC, whereas iHIDiC shows poor exergy efficiency (ηE = 8.09%), even lower than the CDC.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call