Abstract
The corrosion behaviour over time in 0.5 M NaCl of TiCN spark plasma sintered at low temperature (1400°C) with 5 vol% Si aids and its reference pure TiCN spark plasma sintered at high temperature (2100°C) were investigated by electrochemical techniques (i.e., open circuit potential, current-potential curves, and electrochemical impedance spectroscopy) and microstructural characterisation (i.e., optical microscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy), and compared. It is shown that both TiCN materials are very resistant to corrosion in 0.5 M NaCl. After two months of immersion the surfaces remained pristine, without any signs of attack. Their impedance responses revealed capacitive behaviour and very high impedance at low frequencies. The protective passive films strengthened during anodic polarisation and the samples withstood considerable overpotentials before film rupture. The TiCN material fabricated with Si aids is preferable due to its slightly higher corrosion resistance and much lower sintering temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.