Abstract

Stool fluid has been obtained for analysis by homogenization and high speed centrifugation of fresh stool. This fluid, from two healthy individuals with soft stools has been compared with stool dialysate obtained in vivo by retrieval of swallowed dialysis bags from their stools. Stool fluid was more acid, with a higher osmolality, an increased concentration of organic anions, sugar and ammonia, and a lower bicarbonate concentration than dialysate in vivo. It is suggested that in the individuals studied, dialysate in vivo may not be in equilibrium with the stool fluid surrounding it, and may not represent a true dialysate of faecal water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.