Abstract

Introduction: Single Balloon Enteroscopy (SBE) is an important tool in the evaluation and management of small-bowel disease. An enteroscope not yet released by Olympus, the SIF-Y0005, displays a unique combination of two proprietary technologies: passive bending and high force transmission. Cumulatively, this may improve ease of insertion, operator control, and enhance procedural efficiency. In addition, it has a 3.2mm biopsy channel to facilitate instrument insertion. We aimed to evaluate the diagnostic and therapeutic yields, and insertion depth between the prototype and the SIF-180 enteroscope.Table: No Caption available.Table: No Caption available.Table: No Caption available.Methods: A retrospective cohort study of 65 patients undergoing SBE was performed at Tampa General Hospital. Patients were divided into two groups: 39 patients undergoing SBE with the SIF-Q180 (control) vs. 26 with the SIF-Y0005 (prototype). Data on patient demographics, diagnostic yield, therapeutic yield, and insertion depth were compared between groups. The difference for categorical variables was assessed using a X2 test and summarized as odds ratio (OR) with 95% confidence intervals (CI). The difference for continuous variable was assessed using independent samples t-test and summarized as mean difference along with 95% CI. To adjust for multiple comparison, Bonferroni correction was applied. The statistical significance was set at 5% for all comparisons. Results: 54 patients underwent anterograde enteroscopy: 18 patients using the prototype enteroscope vs. 36 using the control. 11 patients underwent retrograde enteroscopy: 8 patients using the prototype enteroscope vs. 3 using the control (p=0.036). The diagnostic yield was higher using the prototype enteroscope, with a 2.1 greater odds of finding an abnormality than when using the control enteroscope, but this did not reach statistical significance [OR 2.1 (0.64-6.84);p=0.336]. Therapeutic yield was found to be higher using the prototype enteroscope, with a 1.45 greater odds of treatment performed, but this did not reach statistical significance, [OR 1.45 (0.53-3.91);p-0.647]. The prototype enteroscope had a further insertion depth, however, this did not reach statistical significance [0.58 (-40.892 - 46.048); p=0.906]. Suc cess rate intubating the ileum and performance of retrograde enteroscopy was 100% with the prototype enteroscope. Conclusion: The prototype enteroscope had better diagnostic and therapeutic yields, and insertion depth, although not reaching statistical significance, which was most likely due to small sample size.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call