Abstract

We compared the rate of all-cause revision of 2 classes of primary anatomic shoulder arthroplasty, stemmed (stTSA) and stemless (slTSA), undertaken with cemented all-polyethylene glenoid components. A large national arthroplasty registry identified 2 cohort groups for comparison, stTSA and l undertaken for all diagnoses between January 1, 2011, and December 31, 2021. A subanalysis from January 1, 2017, allowed capturing of additional patient demographics including American Society of Anesthesiologists score, body mass index, and glenoid morphology. The cumulative percent revision (CPR) was determined using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from Cox proportional hazard models adjusted for age and gender. Of the 7995 stTSA procedures, the CPR at 9 years was 5.6% (95% confidence interval [CI]: 5.0, 6.4), and for 3156 slTSA procedures, the CPR was 4.4% (95% CI: 3.6, 5.5). There was no significant difference in the rate of revision between the study groups (HR=0.76 [95% CI: 0.51, 1.14], P=.189, adjusted for age, gender, humeral head size, humeral fixation, bearing surface, glenoid design, and mean surgeon volume [MSV]). There was an increased rate of revision for stTSA and slTSA undertaken with humeral head sizes <44 mm (stTSA <44 mm vs. 44-50 mm, HR=1.56 [CI: 1.18, 2.08], P=.001; slTSA <44 mm vs. 44-50 mm, HR=2.08 [CI: 1.32, 3.33], P=.001). MSV as a continuous predictor was not a revision risk to stTSA vs. slTSA, but categorically, a low MSV (<10 stTSA+slTSA cases per annum) was associated with a higher revision rate for stTSA (10-20 cases/yr vs.<10 cases/yr, HR=0.72 [CI: 0.55, 0.95], P=.019) but was not in slTSA. Revision rates were increased for stTSA with non-crosslinked polyethylene (XLPE) glenoids vs. XPLE after 2 years (HR=2.20 [CI: 1.57, 3.08], P<.001) but did not significantly differ for slTSA. Metal/XPLE (humeral/glenoid) bearing surface of stTSA rate of revision was not different from each combination of slTSA bearing surface. Instability/dislocation was a revision risk for slTSA vs. stTSA (HR=1.93 [CI: 1.28, 2.91], P=.001), but from 2017, neither of American Society of Anesthesiologists score, body mass index, and glenoid morphology changed the rate of revision. Revision rates of stTSA and slTSA did not significantly differ and were associated with humeral head size but not patient characteristics. Surgeon inexperience of anatomic shoulder arthroplasty and non-XLPE glenoids were risk factors for stTSA revision but not slTSA. The metal/XLPE stTSA rate of revision was not found to differ significantly from slTSA regardless of polyethylene or humeral head bearing type. Revision for instability/dislocation was more common for slTSA.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.