Abstract
The patency rates and healing characteristics during a nine-month period of internal velour Dacron grafts, external velour Dacron grafts, and Sparks-Mandril grown grafts were compared with autogenous jugular veins when used to bypass short segments of the canine femoral artery. Graft thrombosis occurred in three of 11 external velour grafts, in six of 11 internal velour grafts, and in three of 11 Sparks-Mandril grafts, None of 33 autogenous veins occluded. Graft thrombosis was not correlated with the degree of graft healing but rather with a hyperplastic proliferative intimal lesion observed at the proximal anastomosis of the occluded grafts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.