Abstract
The diagnosis of a loose total hip prosthesis is often established with use of radiographic and nuclear medicine techniques, but there is controversy about the relative utility of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy. In this retrospective study, we evaluated the sensitivity, specificity, and interobserver reliability of these imaging modalities in patients suspected of having aseptic loosening of the acetabular component. From 1994 to 1999, eighty-six consecutive patients with pain after a total hip arthroplasty were evaluated for possible loosening of the components. The imaging evaluation included plain radiography followed by a one-day protocol that included bone scintigraphy, subtraction arthrography, and nuclear arthrography. For this study, two experienced nuclear medicine physicians and two experienced radiologists, all of whom were blinded with respect to the clinical pretest data and the clinical outcome, retrospectively interpreted the diagnostic images. The sensitivity and the specificity of each imaging modality were established by comparing the findings obtained with each technique with those found at surgery or during the subsequent clinical course of the patient. Interobserver variability was determined with the intraclass correlation coefficient. Plain radiography had a sensitivity of 85% (95% confidence interval, 71 to 94) and a specificity of 85% (95% confidence interval, 66 to 96) in detecting aseptic loosening of the acetabular component, but it had only fair interobserver variability (intraclass correlation coefficient, 0.37). For subtraction arthrography, the sensitivity was 72% (95% confidence interval, 57 to 84), the specificity was 70% (95% confidence interval, 50 to 86), and there was good interobserver variability (intraclass correlation coefficient, 0.71). For nuclear arthrography, the sensitivity was 57% (95% confidence interval, 41 to 71), the specificity was 67% (95% confidence interval, 46 to 84), and there was fair interobserver variability (intraclass correlation coefficient, 0.24). For bone scintigraphy, the sensitivity was 83% (95% confidence interval, 69 to 92), the specificity was 67% (95% confidence interval, 46 to 84), and there was moderate interobserver variability (intraclass correlation coefficient, 0.43). Plain radiography had the highest diagnostic accuracy in the evaluation of aseptic loosening of the acetabular component. The diagnostic accuracy was increased when plain radiography was combined with bone scintigraphy or subtraction arthrography. However, we found considerable interobserver variability in image interpretation, even with experienced radiologists and nuclear medicine physicians.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of Bone and Joint Surgery-American Volume
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.