Abstract

Synthetic polyglycolic acid (Dexon) sutures were compared with silk or nylon in 50 patients requiring skin surgery. After some practice, polyglycolic acid is an easily handled as nylon or silk. Skin reactions occurred in 50% of the patients sutured with nylon, in 10% of those sutured with polyglycolic acid, and in none sutured with silk. Wound healing was satisfactory in all cases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.